Trace Analyse
Flow / Druck HB1012 0000523
Datensätze
16
1 Kopf
144 Tests gesamt
Pass-Rate
99.3%
↑ 1.4% über 2 Runs
Pass / Fail
143
/
1
2025/11/12 16:31:38 — 2025/11/13 08:24:43
Versorgungsdruck
122 MesspunktePositiv
394.95 kPa
-7
383.95 — 404.95
Negativ (Vakuum)
-91.1 kPa
+1.5
-95.26 — -90.6
Messwert-Drift
48 Trends
| Nozzle | Messung | Trend | Aktuell | Margin | Status |
|---|---|---|---|---|---|
| A | VBD Druck | 17.6 |
+42.7%
|
○ | |
| A | Vac\u{2191} Flow | 11.094 |
+38.7%
|
○ | |
| A | Vac\u{2191} Druck | -93.15 |
+27.4%
|
○ | |
| A | Vac\u{2193} Druck | -93.15 |
+27.4%
|
○ | |
| B | VBD Druck | 17.6 |
+42.7%
|
○ | |
| B | Vac\u{2191} Flow | 10.956 |
+36.9%
|
○ | |
| B | Vac\u{2191} Druck | -93.15 |
+27.4%
|
○ | |
| B | Vac\u{2193} Druck | -93.15 |
+27.4%
|
○ | |
| C | VBD Druck | 17.6 |
+42.7%
|
○ | |
| C | Vac\u{2191} Flow | 10.898 |
+36.2%
|
○ | |
| C | Vac\u{2191} Druck | -93.15 |
+27.4%
|
○ | |
| C | Vac\u{2193} Druck | -93.15 |
+27.4%
|
○ | |
| D | VBD Druck | 17.6 |
+42.7%
|
○ | |
| D | Vac\u{2191} Flow | 10.858 |
+35.7%
|
○ | |
| D | Vac\u{2191} Druck | -93.15 |
+27.4%
|
○ | |
| D | Vac\u{2193} Druck | -93.15 |
+27.4%
|
○ | |
| E | VBD Druck | 17.6 |
+42.7%
|
○ | |
| E | Vac\u{2191} Flow | 11.015 |
+37.7%
|
○ | |
| E | Vac\u{2191} Druck | -93.15 |
+27.4%
|
○ | |
| E | Vac\u{2193} Druck | -93.15 |
+27.4%
|
○ | |
| F | VBD Druck | 17.6 |
+42.7%
|
○ | |
| F | Vac\u{2191} Flow | 10.996 |
+37.5%
|
○ | |
| F | Vac\u{2191} Druck | -93.15 |
+27.4%
|
○ | |
| F | Vac\u{2193} Druck | -93.15 |
+27.4%
|
○ | |
| G | VBD Druck | 17.6 |
+42.7%
|
○ | |
| G | Vac\u{2191} Flow | 11.074 |
+38.4%
|
○ | |
| G | Vac\u{2191} Druck | -93.15 |
+27.4%
|
○ | |
| G | Vac\u{2193} Druck | -93.15 |
+27.4%
|
○ | |
| H | VBD Druck | 17.6 |
+42.7%
|
○ | |
| H | Vac\u{2191} Flow | 10.937 |
+36.7%
|
○ |
Dateiübergreifende Korrelation
HB1012 0000523
Achsen-Bewegungszeit
AxisMoveTime00.txt
16
Einträge
0
Fehler
2
Sessions
Achsen-Drehmoment
AxisTorque00.txt
18
Einträge
0
Fehler
2
Sessions
Kontakterkennung
ContactDetection00.txt
16
Einträge
0
Fehler
2
Sessions
Testläufe (2)
| Nozzle | Run 1 11/12 16:31 |
Run 2 11/13 08:24 |
Trend |
|---|---|---|---|
| A | 1 FailVac↑:Leak | ✓ Pass | ▼ |
| B | ✓ Pass | ✓ Pass | ✓ |
| C | ✓ Pass | ✓ Pass | ✓ |
| D | ✓ Pass | ✓ Pass | ✓ |
| E | ✓ Pass | ✓ Pass | ✓ |
| F | ✓ Pass | ✓ Pass | ✓ |
| G | ✓ Pass | ✓ Pass | ✓ |
| H | ✓ Pass | ✓ Pass | ✓ |
| Date/Time | Serial No | Nozzle | VBD | NC | Vac↑ | Vac↓ | VB-NZL | PU-NZL | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Flow | Press | Flow | Press | Flow | Press | Leak | Flow | Press | Flow | Press | Flow | Press | ||||
| 2025/11/12 16:31:38 | HB1012 0000523 RH08 | A | Pass | Pass | Pass | Pass | Pass | Pass | Fail | Pass | Pass | · | · | · | · | ▸ |
| 2025/11/12 16:31:38 | HB1012 0000523 RH08 | B | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | · | · | · | · | ▸ |
| 2025/11/12 16:31:38 | HB1012 0000523 RH08 | C | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | · | · | · | · | ▸ |
| 2025/11/12 16:31:38 | HB1012 0000523 RH08 | D | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | · | · | · | · | ▸ |
| 2025/11/12 16:31:38 | HB1012 0000523 RH08 | E | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | · | · | · | · | ▸ |
| 2025/11/12 16:31:38 | HB1012 0000523 RH08 | F | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | · | · | · | · | ▸ |
| 2025/11/12 16:31:38 | HB1012 0000523 RH08 | G | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | · | · | · | · | ▸ |
| 2025/11/12 16:31:38 | HB1012 0000523 RH08 | H | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | · | · | · | · | ▸ |
| 2025/11/13 08:24:43 | HB1012 0000523 RH08 | A | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | · | · | · | · | ▸ |
| 2025/11/13 08:24:43 | HB1012 0000523 RH08 | B | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | · | · | · | · | ▸ |
| 2025/11/13 08:24:43 | HB1012 0000523 RH08 | C | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | · | · | · | · | ▸ |
| 2025/11/13 08:24:43 | HB1012 0000523 RH08 | D | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | · | · | · | · | ▸ |
| 2025/11/13 08:24:43 | HB1012 0000523 RH08 | E | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | · | · | · | · | ▸ |
| 2025/11/13 08:24:43 | HB1012 0000523 RH08 | F | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | · | · | · | · | ▸ |
| 2025/11/13 08:24:43 | HB1012 0000523 RH08 | G | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | · | · | · | · | ▸ |
| 2025/11/13 08:24:43 | HB1012 0000523 RH08 | H | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | · | · | · | · | ▸ |